 Embedded Power for Business-Critical Continuity
NFS110 Medical Series
Single and quad output
Rev. 06.10.08 NFS110 Series 1 of 5
Total Power: 80 - 110 W Input Voltage: 90 - 253 Vac 127 - 357 Vdc # of Outputs: Single, quad
Electrical Specifications
Output
Voltage adjustability +5.1 V o/p on multi's 5.1 V single output 12 V single output 15 V single output 24 V single output LL to HL, FL All outputs on all units At turn-on no lead All outputs Multi o/p 5.1 V only 5.1 V single 12 V single 15 V single 24 V single Primary power limited 3.0% 3.0% 12-14 V 15-18 V 24-30 V 0.1% max. 0% 0.02%/C 6.25 V 0.75 V 6.25 V 0.75 V 15.75 V 1.0 V 22 V 1.5 V 33 V 2.5 V Pin max. 160 W Pout min. 110 W Burst mode operation 90-253 Vac 127-357 Vdc 47-440 Hz 110 Vac. 50 Hz 230 Vac. 50 Hz 17 A 35 A 50 A 100 A
Special Features
* 7.0 x 4.25 x 1.8 inch package * Medical, dental and laboratory applications * Overvoltage and short circuit protection * 110 W with 20 CFM * UL, VDE and CSA safety approvals * EN60601-1 and UL2601 medical approvals * Available RoHS compliant * 2 year warranty
Line regulation Overshoot/undershoot Temperature coefficient Overvoltage protection
Output power limit Short circuit protection
Safety
VDE0805/EN60601-1/ IEC601/IEC1010 File No. 10401-3336-1049 Licence No. 2874 UL2601 File No. E147937 CSA C22.2 No. 125 File No. LR41062C
Input
Input voltage range Input frequency range Input surge current
Safety ground leakage current 132 Vac 264 Vac
All specifications are typical at nominal input, full load at 25C unless otherwise stated
Embedded Power for Business-Critical Continuity
EMC Characteristics
Conducted emissions Radiated emissions ESD air ESD contact Surge Fast transients Radiated immunity Conducted immunity EN55022, FCC part 15 EN55022, FCC part 15 EN61000-4-2, level 3 EN61000-4-2, level 4 EN61000-4-3, level 3 EN61000-4-4, level 3 EN61000-4-5, level 3 EN61000-4-6, level 3 110 Vac @ 80 W 110 Vac @ 110 W 230 Vac @ 80 W 230 Vac @ 110 W Multiple outputs +5.1 V single 12 V and 15 V singles 24 V single Input/output Input/chassis Level A Level A Perf. criteria 1 Perf. criteria 1 Perf. criteria 1 Perf. criteria 1 Perf. criteria 2 Perf. criteria 2 35 ms 17 ms 140 ms 100 ms 70% typical 70% typical 72% typical 75% typical 4000 Vac 1500 Vac VDE0750, IEC60601, IEC1010, UL2601 CSA C22.2 No. 125 Singles Multiple outputs MIL-HDBK-217E 550 g (19.4 oz) 600 g (21.2 oz) 125,000 hours min.
Rev. 06.10.08 NFS110 Series 2 of 5
General Specifications
Hold-up time
Efficiency
Isolation voltage Approvals and standards (see note 12) Weight MTBF (@25 C)
Environmental Specifications
Thermal performance (See notes 9, 10) Operating, see curve Non-operating +50 C to +70 C, amb. convection cooled 0 C to +50 C, 20 CFM forced air +50 C to +70 C, 20CFM forced air Relative humidity Altitude Vibration (See Note 11) Non-condensing Operating Non-operating 5-500 Hz 0 C to +70 C -40 C to +85 C Derate 2 W/C 110 W Derate 2.75 W/C 5% to 95% RH 10,000 feet max. 40,000 feet max. 2.4 G rms peak 0 C to 50 C amb. convection cooled 80 W
Peak, 0 C to +50 C, max. 60 seconds 110W
Embedded Power for Business-Critical Continuity
Ordering Information
Output Voltage +5.1 V +12 V -12 V -5 V +5.1 V (IA) +24 V (IB) (6) +12 V -12 V +5.1 V +15 V -15 V -5 V 12 V 15 V 24 V Output Currents Max 8A 4.5 A 0.5 A 0.5 A 8A 3.5 A 4.5 A 0.5 A 8A 4A 0.5 A 0.5 A 7A 5A 3.5 A
(1)
Rev. 06.10.08 NFS110 Series 3 of 5
Peak (2) 20 A 9A 1.5 A 1.5 A 20 A 4.5 A 9A 1.5 A 20 A 7.5 A 1.5 A 1.5 A 9A 7.3 A 4.5 A
Fan (3) 10 A 5A 1A 1A 10 A 4.5 A 5A 1A 10 A 5A 1A 1A 9A 7.3 A 4.5 A
Ripple (4) 50 mV 120 mV 120 mV 50 mV 50 mV 240 mV 120 mV 120 mV 50 mV 150 mV 150 mV 50 mV 120 mV 150 mV 240 mV
Total Regulation (5) 2.0% 3.0% 3.0% 3.0% 2.0% +10/-5.0% 3.0% 3.0% 2.0% 4.0% 3.0% 3.0% 2.0% 2.0% 2.0%
Model Numbers (13, 14, F) NFS110-7901PJ
NFS110-7902PJ
NFS110-7904PJ
NFS110-7912J (7,8) NFS110-7915J (7,8) NFS110-7924J (7,8)
Notes
1 2 3 4 5 Convection cooled, 80 W maximum. Peak outputs lasting less than 60 seconds with duty cycle less than 10%. Total peak power must not exceed 110 W. Forced air, 20 CFM at 1 atmosphere, 110 W maximum. Figure is peak-to-peak. Output ripple is measured across a 50 MHz bandwidth using a 12 inch twisted pair terminated with a 47 F capacitor. Total regulation is defined at the static output regulation at 25 C, including initial tolerance, line voltage within stated limits and output voltages adjusted to their factory settings. Also for NFS110-7902PJ, for 24 V output stated regulation IA / IB 5. This output will maintain 5.0% regulation if IA 5 A, where IA = +5.1 V output current and IB = +24 V output current. Single output models have floating outputs which may be referenced as either positive or negative. Higher voltage supplies, may be adjusted over a wide output voltage range, as long as the total output power does not exceed 80 Watts (natural convection) or 110 Watts (forced air). Power fail detect not available on single output models. Derating curve is application specific for ambient temperatures > 50 C, for optimum reliability no part of the heatsink should exceed 90 C and no semiconductor case temperature should exceed 100 C. Caution: Allow a minimum of 1 second after disconnecting the power when making thermal measurements. The user should read the PSU installation instructions in conjunction with the relevant national safety regulations in order to ensure compliance. Three orthogonal axes, random vibration, 10 minute test for each axis. This product is only for inclusion by professional installers within other equipment and must not be operated as a stand alone product. The `J' suffix indicates that these parts are Pb-free (RoHS 6/6) compliant. TSE RoHS 5/6 (non Pb-free) compliant versions may be available on special request, please contact your local sales representative for details. NOTICE: Some models do not support all options. Please contact your local Emerson Network Power representative or use the on-line model number search tool at http://www.powerconversion.com to find a suitable alternative.
TRANSIENT RESPONSE NFS110-7901PJ +5.1 V (7.5-10 A) +12 V (2.5-5 A) -12 V (0.5-1 A) -5 V (0.5-1 A) NFS110-7902PJ +5.1 V (7.5-10 A) +12 V (2.5-5 A) -12 V (0.5-1 A) 24 V (1.5-3 A) NFS110-7904PJ +5.1 V (7.5-10 A) +15 V (2.5-5 A) -15 V (0.5-1 A) -5 V (0.5-1 A) NFS110-7905J NFS110-7912J NFS110-7915J NFS110-7924J +5.1 V (10-20 A) +12 V (4.5-9 A) +15 V (3.65-7.3 A) +24 V (2.25-4.5 A) 150 mV peak, 1 ms recovery 100 mV peak, 0.5 ms recovery 100 mV peak, 0.5 ms recovery 100 mV peak, 0.5 ms recovery 150 mV peak, 1 ms recovery 100 mV peak, 0.5 ms recovery 100 mV peak, 0.5 ms recovery 300 mV peak, 1 ms recovery 150 mV peak, 1 ms recovery 100 mV peak, 0.5 ms recovery 100 mV peak, 0.5 ms recovery 100 mV peak, 0.5 ms recovery 250 mV peak, 1 ms recovery 360 mV peak, 1 ms recovery 450 mV peak, 1 ms recovery 720 mV peak,
6
7 8 9 10 11 12 13 14
Embedded Power for Business-Critical Continuity
Rev. 06.10.08 NFS110 Series 4 of 5
AC (J1) mating connector
Molex 09-50-3051 or Molex 09-91-0500 mating connector with 2478 or equivalent crimp terminals.
OPTIONAL POWER FAIL DETECT TIMING DIAGRAM AC INPUT 4.75V 5V OUTPUT HIGH PFD SIGNAL LOW 0-0.4 MAX T1 T2 3.5V MIN T3 4.75V
Power fail detect signal (Note 8)
50ms T1 200ms T2 will vary with line and load T3 3ms Pout: 110W PFD output is an open collector which will sink 40mA in the low state.
DC (J2) mating connector
Molex 09-50-3131 or Molex 09-91-1300 mating connector with 2478 or equivalent crimp terminals.
0.475 0.010 (12.07)
1.80 (45.72) MAX
1.00 0.005 (25.4)
DERATING CURVE (See Notes 9, 10)
0.050 0.020 (1.27) 3.35 0.015 (85.09) 1.55 0.005 (39.37) Voltage Adjust Optional Power Fail Detect Circuit (Key = Pin 2) T1 T1 Pin 1 PIN 1 L1
11W
6-32 UNC (4PL) PIN 1
Output Power (Watts)
110W
20 CFM FORCED AIR COOLING
80W
J2
4.250 0.020 (107.95) 3.750 0.005 (95.25)
NATURAL CONVECTION COOLING
55W 40W
J1 C6 F1
0.156 DIA. HOLE (4PL)
0W 0C
11W MINIMUM LOAD REQUIRED AT 230VAC
10C 20C 30C 40C 50C 60C 70C
0.250 0.010 (6.35) 0.250 0.010 (6.35)
5A, 250 VAC 6.50 0.005 (165.1) 7.00 0.020 (177.8)
Pin Connections J1 Pin 1 -7901PJ AC Ground AC Neutral AC Line -7902PJ AC Ground AC Neutral AC Line -7904PJ AC Ground AC Neutral AC Line SINGLES AC Ground AC Neutral AC Line
ALL DIMENSIONS IN INCHES (mm)
Mechanical Notes
A Metallic or non-metallic stand-offs (maximum diameter 5.4mm) can be used in all four mounting holes without effecting safety approval. B The ground pad of the mounting hole near J1, allows system grounding through a metal stand-off to the system chassis. C The heat sink is grounded, and allows system grounding by mechanical connection to the system chassis. D The supply must be mechanically supported using the PCB mounting holes and may be additionally supported by the heatsink mounting holes. E It is always advisable to attach the power supply heat sink to another thermal dissipator (such as a chassis or finned heatsink etc). The resulting decrease in heat sink mounted component temperatures will improve power supply lifetime. F A standard L-bracket and cover is available for mounting which contains all screws, connectors and necessary mounting hardware. The kit is available, order part number "NFS110CJ".
Pin 2 Pin 3 J2 Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Pin 8 Pin 9 Pin 10 Pin 11 Pin 12 Pin 13
+5.1 V +5.1 V +5.1 V Return Return Return Return +12 V +12 V PFD -12 V
+5.1 V +5.1 V +5.1 V Return Return Return Return +12 V +12 V PFD -12 V
+5.1 V +5.1 V +5.1 V Return Return Return Return +15 V +15 V PFD -15 V
Vout Vout Vout Return Return Return Return Vout Vout N/C N/C
Removed for Key -5 V +24 V -5 V N/C
N/C = no connection.
Embedded Power for Business-Critical Continuity
Americas
5810 Van Allen Way Carlsbad, CA 92008 USA Telephone: +1 (760) 930 4600 Facsimile: +1 (760) 930 0698
Rev. 06.10.08 NFS110 Series 5 of 5
Europe (UK)
Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355
Asia (HK)
14/F, Lu Plaza 2 Wing Yip Street Kwun Tong, Kowloon Hong Kong Telephone: +852 2176 3333 Facsimile: +852 2176 3888
For global contact, visit:
www.powerconversion.com technicalsupport@ powerconversion.com
While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions.
Emerson Network Power. The global leader in enabling business-critical continuity. AC Power Connectivity DC Power Embedded Computing Embedded Power Monitoring Outside Plant Power Switching & Controls Precision Cooling Racks & Integrated Cabinets Services Surge Protection EmersonNetworkPower. com
Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. (c)2008 Emerson Electric Co.


▲Up To Search▲   

 
Price & Availability of NFS110-7904PJ

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X